Bettis BLF Single-Acting Linear Actuators
Technical Data
Working pressure: 135 bar / 2000 psi
Test pressure: 1.5 x working pressure to a maximum of 250 bar / 3600 psi
Temperature range: -20˚ to +80˚C / -5˚ to +180˚F
End closing thrust (spring): 1500 – 16500 N / 1100 to 12000 lbf
Viscosity of hydraulic oil: 15 to 200 cSt
The Bettis BLF/BLFR actuator for fail close operation of globe valves
Features
• Unique and simple design with integrated crossover valve
• Easy installation on intermediate flange of globe valve
• Same unit for various valve sizes
• Water ingress protection – IP68
• No external moving parts
• Design ready for control functions
• Built-in hydraulic emergency operation for the BLFR
• Direct visual indication